Unimedsume Trading Co., Ltd

Produk-produk

Home > Produk-produk > Peralatan makmal > Spectrophotometer > Api / Gentian Grafit Spektrofotometer Penyerapan Atom

Api / Gentian Grafit Spektrofotometer Penyerapan Atom

Jenis bayaran:
L/C,T/T,D/P,Paypal,Money Gram,Western Union
Incoterm:
FOB,CFR,CIF,EXW,FCA,CPT,CIP
Pesanan minimum:
1 Piece/Pieces
Pengangkutan:
Ocean,Land,Air
Port:
Jinan,Qingdao,Shanghai
Share:
  • Penerangan produk
Overview
Atribut Produk

JenamaUMS

Membekalkan Keupayaan & Maklumat Tambaha...

PembungkusanPakej Eksport

PengangkutanOcean,Land,Air

Tempat asalChina

PortJinan,Qingdao,Shanghai

Jenis bayaranL/C,T/T,D/P,Paypal,Money Gram,Western Union

IncotermFOB,CFR,CIF,EXW,FCA,CPT,CIP

Pembungkusan & Penghantaran
Unit Jualan:
Piece/Pieces
Jenis Pakej:
Pakej Eksport
Api / Gentian Grafit Spektrofotometer Penyerapan Atom

CIRI-CIRI:


Teknik analisis api oksigen udara-asetilena yang kaya dengan inovatif (UFX-110A)

T dia dipatenkan teknik analisis api menggunakan api oksigen udara-asetilena yang kaya sebagai penggantian nyalaan nitro oksida-asetilena untuk analisis elemen suhu tinggi, seperti Ca, Al, Ba, W, Mo, Ti, V, dan lain-lain. Suhu api berterusan laras antara 2300-2950 , yang memungkinkan untuk memilih suhu pengabusan yang terbaik untuk unsur-unsur yang berbeza. Ia mempunyai operasi yang mudah, kos analisis yang rendah dan jangkauan analitik AAS yang luas. Api oksigen yang kaya tidak akan mencemarkan alam sekitar dan tidak membahayakan tubuh manusia. Ini adalah analisis break AAS dalam api.


Sistem pengaburan api api / grafit bersepadu, boleh diubah dengan pembakar pelepasan api


  • Pengubahsuaian secara automatik dari penyalaan nyalaan api dan grafit bersepadu yang memperlihatkan operasi mudah dan penjimatan masa menghapuskan tenaga kerja manusia.
  • Kepala pembakaran pelepasan nyalaan dapat dipasang untuk melakukan analisis pelepasan nyala ke logam Alkali sebagai K, N dan sebagainya (UFX-110A / 120A)


Sistem kawalan sepenuhnya automatik yang tepat

  • Turret berbilang lampu automatik, pelarasan automatik semasa lampu dan pengoptimuman kedudukan pancaran cahaya.
  • Pengimbasan panjang gelombang automatik dan pemetik puncak
  • Lebar jalur spektrum automatik berubah
  • Peralihan automatik antara operasi relau api dan grafit, pengoptimuman automatik parameter kedudukan, dan pencucuhan automatik


Analisis relau grafit automatik sepenuhnya dipercayai

  • Mengamalkan mod kawalan suhu FUZZY-PID dan dual curve kawalan suhu automatik, teknik auto-pembetulan suhu, memastikan pemanasan pantas, kebolehsuaian suhu yang baik dan kepekaan analisis yang tinggi. Ketepatan kawalan suhu kurang daripada 1%.
  • Relau grafit dengan kawalan pneumatik dan kunci tekanan memastikan tekanan malar dan hubungan yang boleh dipercayai.


Langkah perlindungan keselamatan yang sempurna

  • Penggera dan perlindungan automatik untuk kebocoran gas bahan bakar, aliran tidak normal, tekanan udara tidak mencukupi dan kepupusan api tidak normal dalam sistem api;
  • Fungsi penggera dan perlindungan kepada gas pembawa yang tidak mencukupi dan tekanan gas pelindung, bekalan air penyejuk yang tidak mencukupi dan sistem pemanasan grafit yang terlalu panas.


Reka bentuk elektronik yang maju dan boleh dipercayai

  • Mengguna pakai pelbagai logik diprogram secara besar-besaran dan teknologi bas Inter Inter I2C
  • Soket jenis Eropah dan penyesuai AMP dengan kebolehpercayaan yang tinggi untuk memastikan kebolehpercayaan jangka panjang sistem elektronik keseluruhan.


Perisian analisis mudah dan praktikal

  • Perisian analisa AAS yang mudah digunakan dibuat di bawah sistem pengendalian Windows, menyedari penentuan parameter pantas dan pengoptimuman.
  • Paparan automatik data yang diukur, pengiraan automatik dan hasil analisis secara automatik dicetak.


SPESIFIKASI:

Main Specification

Wavelength range

190-900nm

Wavelength accuracy

±0.25nm

Resolution

Two spectral lines of Mn at 279.5nm and

279.8nm can be separated with the spectral

bandwidth of 0.2nm and valley-peak energy

ratio less than 30%.

Baseline stability

≤0.004A/30min

Background correction

The D2 lamp background correction

capability at 1A is better than 30 times.   

The S-H background correction capability at

1.8A is better than 30 times. (only for

UFX-110A/120A)

Hollow Cathode

Lamps

Lamp turret

6-lamp turret (UFX-110A/120A),

4-lamp turret (UFX-130A)

Auto-alignment, fully automated scan and

peak-picking.

Lamp current

adjustment

Automatic adjustment and display.

Wide pulse current: 0~25mA,              Narrow pulse current: 0~10mA                  

Lamp power supply

mode

400Hz square wave pulse

100Hz Narrow square wave pulse + 400Hz

wide square wave pulse (UFX-110A/120A)

Optical System

Monochomator

Single beam, Czerny-Turner design grating monochromator

Grating

1800 l/mm

Focal length

277mm

Blazed Wavelength

250nm

Spectral Bandwidth

0.1nm, 0.2nm, 0.4nm, 1.2nm automatic

change.

Flame Atomizer

Burner

10cm single slot all-titanium burner    

Spray chamber

Corrosion resistant all-plastic spray chamber.

Nebulizer

High efficiency glass nebulizer with metal

sleeve, sucking up rate: 6-7mL/min

Emission burner

Provided with UFX-110A/120A

Graphite Furnace

Temperature range

Room temperature~3000ºC

Heating rate

2000/s

Graphite tube dimensions

28mm (L) x 8mm (OD)

Characteristic mass

Cd≤0.8 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g

Precision

Cd≤3%, Cu≤3%, Mo≤4%

Detection and Data

Processing System

Detector

R928 Photomultiplier with high sensitivity and

wide spectral range.

Software

Windows operating system

Analytical method

Working curve auto-fitting; standard addition

method; automatic sensitivity correction;

automatic calculation of concentration and

content.

Repeat times

Maximum 20 times of repeat measurement,

automatic calculation of mean value,

standard deviation and relative standard

deviation.

Multi-task function

Sequential measurement of multi-elements in

one sample

Condition reading

With model function

Result printing

Measurement data and final analytical report

printout, editing with Excel.

Standard RS-232 serial port communication

Characteristic

Concentration and

Detection Limit

Normal Air-C2H2 flame

Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;

Oxygen-rich Air-C2H2

flame

Ba:  Characteristic concentration ≤ 0.22mg/L

Al:  Characteristic concentration ≤ 0.4mg/L (for UFX-110A)

Function Expansion

Hydride vapor generator can be connected for hydride analysis.

Dimensions and weight

1020 (L) × 490(W) × 540 (H) mm (main unit), unpacked 80kg

420 (L) × 420 (W) × 460 (H) mm (graphite furnace), unpacked 50kg


Wfx 110a 120a 130a

Kategori produk : Peralatan makmal > Spectrophotometer

E-mel kepada pembekal ini
  • *Subjek:
  • *Untuk:
    Mr. Frank
  • *E-mel:
  • *Mesej:
    Mesej anda mestilah antara watak-watak 20-8000

Home > Produk-produk > Peralatan makmal > Spectrophotometer > Api / Gentian Grafit Spektrofotometer Penyerapan Atom

Hantar pertanyaan
*
*

Hantar pertanyaan

Frank

Mr. Frank

Tel:0086-0531-86077860

Fax:

Telefon mudah alih:+8615666779750Contact me with Whatsapp

E-mel:

Alamat:

Tapak Mudah Alih

Rumah

Product

Whatsapp

Tentang kita

Siasatan

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Menghantar